       UL94 flame retardant rating test

      UL94 flame retardant rating is the most widely used material flame retardant performance evaluation standard. It is used to evaluate the ability of materials to extinguish after being ignited and is a commonly used standard for daily testing of material flame retardancy. There are multiple evaluation methods for UL94 based on the combustion rate, combustion time, droplet resistance, and whether the droplets burn after ignition of the material.

       

      UL94 has a total of 12 levels:

       

      HB, V-0, V-1, V-2, 5VA, 5VB, VTM-0, VTM-1, VTM-2, HBF, HF1, HF2

       

      Among them, VTM-0, VTM-1, and VTM-2 are suitable for plastic film, while HBF, HF1, and HF2 are suitable for foam materials

       

      The level testing plan is as follows:

      1) HB level: Horizontal Burning Test

      2) V0-V2 level: Vertical Burning Test

      3) 5VA/5VB: 5V level fire test 500w (125 mm) vertical burning test

      4) RP Class: Radiant Panel Flame Spread Test

      5) VTM0-VTM2: Thin Material Vertical Burning Test

      6) HF1-HF2: Horizontal Burning Foam Material Test

       

      The specific testing requirements for UL94 are as follows:

       

      HB: Flame retardant rating in UL94 standard. Require a combustion rate of less than 40 millimeters per minute for samples with a thickness of 3 to 13 millimeters; Samples less than 3 millimeters thick have a combustion rate of less than 70 millimeters per minute; Or extinguish before the 100mm mark.

       

      V-0: After conducting two 10 second combustion tests on the sample, the residual flame and residual flame will extinguish within 30 seconds. Dropping particles cannot ignite cotton.

       

      V-1: After conducting two 10 second combustion tests on the sample, the residual flame and residual flame will extinguish within 60 seconds. Dropping particles cannot ignite cotton.

       

      V-2: After two 10 second combustion tests on the sample, the residual flame and residual flame will extinguish within 60 seconds. Dripping particles can ignite cotton.

       

      5VB: After conducting five 5-second combustion tests on the sample, the residual flame and residual flame will extinguish within 60 seconds. Dropping particles cannot ignite cotton. For block samples, it is allowed to be burned through.

       

      5VA: After conducting five 5-second combustion tests on the sample, the residual flame and residual flame will extinguish within 30 seconds. Dropping particles cannot ignite cotton. It is not allowed to burn through block samples.

       

      Common UL94 testing methods

      1. Horizontal Combustion Test (HB)

      2. 50W vertical combustion test

      3.500W vertical combustion test

       

      UL 94 Flame Retardant Rating Criteria

      1. UL94 horizontal combustion judgment conditions


      Burning rate

      Flame retardant rating

      Sample thickness 3-13mm

      40mm/min

      HB

      Sample thickness 3mm

      75mm/min

      HB

      The flame goes out before the marking   line

      =0 mm/min

      HB

      2. UL94 vertical combustion judgment conditions

      Judgment condition

      V-0

      V-1

      V-2

      Spontaneous combustion time after   applying flames

      10

      30

      30

      Total self ignition time (s)

      (10   spontaneous combustion times)

      50

      250

      250

      Spontaneous combustion after the second   flame application

      +Crimson time (s)

      30

      60

      60

      Droplets ignite cotton

      no

      no

      yes

      Burn to fixture (sample completely   burned)

      no

      no

      no

      3. UL94 500w vertical combustion judgment conditions


      5VA

      5VB

      Any sample spontaneously ignites after 5   flame applications+Crimson time (s)

      60

      60

      Droplets ignite cotton

      no

      no

      Sample perforation ( 3mm)

      no

      yes

       

      Please consult NormalTCI for specific questions

      National Unified Service Hotline: 400-6177-880

      Email [email protected]

      Copyright @ 2015 NORMAL (HANGZHOU) TESTING & CERTIFICATION CO., LTD.  

      Tell:+86-571-28906690  E-mail:[email protected]  Service Hotline:400-6177-880  Fax:+86-571-28867000

      If you have any comments on the website, please email to:[email protected]

        <kbd id="k9gkf"><form id="k9gkf"></form></kbd>

      1. <b id="k9gkf"><menuitem id="k9gkf"></menuitem></b>
        <b id="k9gkf"><menuitem id="k9gkf"></menuitem></b>

      2. <span id="k9gkf"><sup id="k9gkf"></sup></span>
        1. <del id="k9gkf"><form id="k9gkf"></form></del>
          国产视频黄色精频大全 | 人人妻人人澡欧美91精品 | 蘑菇视频91| 欧美特一级 | 啪啪流水视频 |